Prefabricated Chambers of Unilateral Service PCUS-393-MB
Prefabricated Chambers of Unilateral Service (PCUS) are designed for the reception, metering, and distribution of three-phase AC electrical power with a rated voltage of 380/220 V and a frequency of 50 Hz. They are used in solidly grounded neutral systems to protect outgoing feeders against overloads and short-circuit currents.
Conclusions and Certificates (click here)
price on request
X
Leave your contacts and specify a convenient time for the call
Already received another commercial offer? Receive from us a 5% discount on the amount in the estimate!
The PCUS-393-MB series is manufactured using vacuum circuit breakers, load-break switches, disconnectors, and other electrical apparatus, together with modern relay protection and automation systems. The main circuit diagrams and brief technical characteristics are provided in Table 1.
The general arrangement and overall dimensions of the chambers are shown in Figure 1.
Secondary circuits are manufactured according to standard wiring diagrams or the customer's project documentation.
The operational supply voltage and the relay protection equipment are specified by the project documentation (technical questionnaire).
The switchgear assembly is configured in accordance with the technical questionnaire.
Individual components of the switchgear, including chambers, bus bridges, and other elements, can also be manufactured separately.
Climatic design: U3 in accordance with GOST 15150.
Degree of protection in accordance with GOST 14254:
IP20 — front side of the enclosure (with the doors closed) and side walls of the chambers.
IP00 — remaining chamber sections.
To order a switchgear assembly, a completed technical questionnaire must be submitted, including the single-line diagram, equipment parameters, and the layout of the PCUS chambers within the switchgear.
Fig. 1Scheme. 1
Parameter
Value
Rated voltage (line-to-line), kV
6; 10
Maximum operating voltage, kV
7.2; 12
Rated power supply frequency, Hz
50
Rated current of main circuits (except chambers with load-break switches), A
400; 630; 1000
Rated current of main circuits with load-break switches, A
400
Rated current of busbars, A
630; 1000
Rated current of bus bridges, A
630; 1000
Rated current of power fuse links, A
2 to 100
Electrodynamic withstand current, kA, max.
51
Thermal withstand current, kA, max.
20
Duration of thermal withstand current, max.:
– for 400 A and 630 A chambers
2
– for 1000 A chambers
3
Rated voltage of operational circuits (specified upon ordering)
220 V AC or DC
Table 1.1.1 Technical Specifications